суббота, 4 августа 2012 г.

Второй пошел!

Сезон обновлений для Robot в самом разгаре. Встречаем второй сервис пак:

  • для версии х64 качаем тут
  • для версии х32 качаем тут
Список изменений:


General
  1. Loosing a family material while updating a structure from Robot to Revit has been corrected.
  2. Chinese hot-rolled section database data has been corrected.
  3. Creating a new database using the Section Database menu command has been fixed.
  4. Highlighting the erroneous lines in the editor for the text file structure definition has been fixed.
  5. Some fatal errors, registered by CER, have been fixed.
  6. Displaying the German text in the Section Properties dialog has been fixed.
  7. Robot Extension Spreadsheet Calculator issues which blocked access to the sheets, creating a new sheet and setting English units have been removed.
Model Definition
  1. Changing the panel parameters (thickness, calculation model and reinforcement parameters) has been prevented for the contour geometry changes.
  2. Duplicating a self-weight load and finite element linear loads while pasting parts of a structure copied from another model has been fixed.
  3. Generating automatic load combinations according to the SNiP 2.01.07-85 code has been fixed.
  4. Accidental inversion of the load direction for cladding loads has been fixed.
  5. Displaing the notional load on panels and panel numbers in the load table has been fixed.
  6. Opening section databases while analyzing library structures has been fixed.
  7. Importing the *.dxf files has been unblocked.
  8. Keeping the projected load checkbox state while closing the uniform bar load dialog has been fixed.
  9. Updating the Young modulus for existing panels while editing the panel thickness has been fixed.
  10. Launching the kernel calculation engine with German language messages has been fixed.
Analysis and Results
  1. The issue of non-converging modal analysis after the load to mass conversion has been fixed.
  2. Ignoring concentrated bar forces defined with generation of a calculation node during the load to mass conversion has been corrected.
  3. P-delta buckling analysis for a bar structure may now be performed without displaying error 150.
  4. Results for a self-weight load with a negative coefficient have been fixed.
  5. Printing tables in the form as seen in the preview screen has been fixed.
  6. API enum I_CBALCT_OTHER value has been fixed to 3.
R/C Beams Design
  1. Required reinforcement calculation for the SNiP 52-01-2003 code has been fixed.
  2. Graphical presentation of grouped bars on a beam cross-section has been corrected.
  3. Taking into account the allowed multiplicity of the stirrup spacing has been fixed.
  4. Issues concerning the anchorage length of the reinforcement have been fixed.
  5. An incorrect load factor for concentrated and surface live loads defined in the loads dialog for the French codes has been corrected.
Steel Connections Design
  1. Verification of welds according to the CM66 code for the pinned column base has been fixed.
  2. An unwanted change of the bolt shear plane while reading the old examples has been fixed.
  3. An error message while opening the window with connection parameters has been fixed.
  4. Incorrect inclination angles of the two-sided beam to column flange connection according to the CM66 code imported from a model has been fixed.
Steel Members Design
  1. Comparison with the minimum yield stress value, as given in the point 6.1 of the AISC 341-05 code has been fixed.
  2. Calculation of critical forces (Nc) and the nominal in-plane member moment capacity (Miz) according to the AS4100 code has been fixed.
  3. Display of the verification formula 13.8.2(a) for the CAN/CSA S16-09 code has been fixed.


Service Pack 2 resolves the following issues: 

ESP-9602; ESP-9603; ESP-9604;
REX-5490;
RM-13628; RM-19531; RM-21754; RM-21877; RM-22509; RM-22715; RM-24050; RM-24241; RM-25355; RM-25463; RM-26794; RM-26843; RM-26897; RM-27022; RM-27041; RM-27043; RM-27046; RM-27047; RM-27048; RM-27090; RM-27098; RM-27119; RM-27120; RM-27126; RM-27143; RM-27147; RM-27162; RM-27163; RM-27166; RM-27174; RM-27177; RM-27186; RM-27188; RM-27190; RM-27191; RM-27192; RM-27197; RM-27204; RM-27207; RM-27226; RM-27233; RM-27241; RM-27246; RM-27249; RM-27251; RM-27340

10 комментариев:

  1. Сталкивася ли кто-то с проблемой армирования в плите? Плита имеет сложную форму, и на ВНУТРЕННИХ углах формы своей модуль теоретического армирования показывает значительно высокие значения площади арматуры. (кнопочка понижение на порох усилий включена)
    плита свободно опертая по контуру на стены

    ОтветитьУдалить
  2. Столкнулись с проблемами с 13-м роботом, установленном на Windows 7.

    1. Не работает команда (геометрия/поверхность) создается не поверхность для распределения нагрузок, а геометрическая фигура, которая игнорируется расчетом. Заданные нагрузки через инструмент "покрытие" не передаются на конструкцию.

    2. Не происходит переключение между рабочими пространствами при включённом сетевом подключении. Программа виснет наглухо.

    Сервиспак установлен последний. На машинах с Win XP таких глюков не наблюдается.

    ОтветитьУдалить
    Ответы
    1. Можно попробовать очистить папку Temp и переименовать пользовательскую папку CfgUsr по адресу C:\Users\username\AppData\Roaming\Autodesk\Autodesk Robot Structural Analysis 2013\CfgUsr\. Затем попробовать создать новый проект и проверить корректность работы.

      Удалить
  3. Вы файлик пришлите а мы над ним поколдуем. То что у вас установлен Вин7 и СП2 еще ни о чем не говорит.

    ОтветитьУдалить
  4. Дело не в файле - передавал своему товарищу, у него всё корректно работает и передаётся.
    Думал может это известная проблема и уже есть готовое решение.

    Дополнение к пункту 2: как только отключаем ноутбук от сети - Robot отвисает и происходит переключение на рабочее пространство.

    ОтветитьУдалить
  5. Попробуйте переустановить винду со всеми дровишками и переустановить сам Робот
    ЗЫ а битность винды какая ???

    ОтветитьУдалить
  6. битность - то, что надо , а вот переустановкой наверное прийдется заняться

    ОтветитьУдалить
  7. Оказалось дело в сетевых принтерах. Болтались неподключённые. Настроил, всё заработало.

    ОтветитьУдалить